ISL71590SEH Rad Hard Temp Sensor

Added on November 06, 2013
See how ISL71590SEH 2-pin temp sensor outperforms the industry standard with assured accuracy in low-dose and high-dose rate radiation environments.

Related Resources

ISL71590SEH Datasheet ISL71590SEH Datasheet

isl71590seh.pdf (535 KB)
Oct 2016

ISL71590SEHEV1Z User Guide ISL71590SEHEV1Z User Guide

an1844.pdf (453 KB)
Oct 2013

Space Products Space Products

br-558.pdf (1.87 MB)
Nov 2017

 


Video Transcript

Hello, my name is Josh Broline, Product Marketing Manager for Intersil Space Products. Today I'd like to talk to you about one of the most critical aspects of a given satellite system design and that is temperature monitoring or temperature sensing.

There are a couple of ways to implement temperature sensing today. One is a device called the 8590, is a two pin temperature sensor, also thermistors or RTD's are commonly used as well. When a user has used this device called the 8590, there is a lot of concern because of the radiation performance that it will not perform as needed over the total mission life. As you can see, the performance is off by as much as 10 degrees C of accuracy error just over 25 kilorads of low dose rate. Often times, this level of total dose is not acceptable enough for most mission lives. Also you can see the performance of high-dose rate, though not as bad, it still degrades pretty good up to a hundred kilorads of total dose.

So in some cases, it may get to the point, if it's a very long mission, where they actually have to shutdown that part of the circuitry to make sure, A, it does not interfere with another part of the satellite, or B, they just don't care anymore about what that particular part of the satellite is providing them.

With the new Intersil ISL71590SEH, you now have a simple solution that is radiation assured over low-dose rate and high-dose rate. Right away at low-dose rate, you'll notice the linearity or the graceful degradation of the performance this device over a wide range of low and high-dose rate exposure. For this device, we guarantee our solution, wafer by wafer, up to 50 K-rads of total dose. Again you can see there that the performance is within 1 degree C of accuracy out to 50 K-rads of total dose.

Furthermore, we took this device and we exposed it to 150 kilorads, and you can see it still has a nice graceful degradation. We took our solution out to 300 kilorads of total dose and were within 1 degree C of accuracy. Again, just showing the superior performance of our solution.

So with the ease-of-use of implementing this two-pin device that does not need external components to make the device linear over temperature, and the assurance that our specifications and our manufacturing capability provides, you'll have a device that you can count on for whether it's a mission that is one year or say 15 years long.

I encourage you to go to Intersil's website and more specifically www.intersil.com/isl71590seh for more information, such as a comprehensive data sheet with typical curves and radiation curves, a single event report, total dose report, and evaluation report.