ISL6121
Single Supply Integrated Current Limiting Controller

Typical Diagram

enlarge +typical diagram

Key Features

    • 0.05ΩΩ Integrated Power N-channel MOSFET Switch
    • Accurate Current Sensing and Limiting
    • 12ms Timed Fault Latch-Off, No thermal Dependency
    • 2.5V to 5.5V Operating Range
    • Under Voltage Lockout
    • Disabled Output Internally Pulled Low
    • Controlled Turn On/Off Ramp Times
    • Fault Output Signal
    • Logic Level Enable High Inputs (ISL6121H) or Enable Low Inputs (ISL6121L)
    • Logic Level Compatible Enable Input and Fault Output
    • Pb-Free Available (RoHS Compliant)

Description

The ISL6121 is a single supply Overcurrent (OC) fault protection IC for 2.5V to 5V applications where 2A current limiting is desired. This device features internal current monitoring and limiting along with a 50mΩ integrated power switch and a current limited time out to latch-off feature for system protection. The time to latch-off is independent of device temperature, and magnitude of OC.

Each ISL6121 incorporates in a 8 lead SOIC package a 50mΩ N-channel MOSFET power switch for power control. The switch is driven by a constant current source giving a controlled ramp up of the output voltage. This provides a soft start turn-on eliminating bus voltage drooping caused by inrush current while charging heavy load capacitances. (Enable high (ISL6121H) and enable low (ISL6121L) options are) available with a fault reporting output compatible with 3V and 5V logic level signals allowing for external control and monitoring.

The Under Voltage (UVLO) lockout feature prevents turn-on of the output unless the correct ENABLE signal and VIN > 2.5V are both present. During initial turn-on the ISL6121 design prevents a fault from being presented by blanking the fault signal, unlike other vendor devices needing additional external circuitry to accomplish this. Rising and falling output is a current-limited voltage ramp so that both the inrush current and voltage slew rate are limited, independent of load. This reduces supply droop due to surge and eliminates the need for external EMI filters. During operation once an OC condition is detected the output is current limited to 2A to allow for a transient condition to pass. If still in current limit after the current limit period has elapsed the output is latched off and the fault is reported by pulling the FAULT low. The FAULT signal is latched low until reset by the enable signal being deasserted at which time the FAULT signal will clear.

Applications

    • Fibre Channel
    • Industrial Power Control
    • Hot Plug

Alternatives

Design Tip

What are the MOSFET Driver Dynamics and Current Sense Methods that one needs to be concerned about in PWM Converters?

See More »

Is there somewhere I can find out what simulations and models (e.g. Spice, PSpice, IBIS) are available on your website?

See More »

iSIM Simulator

Select a category to start designing:

Enter design requirements:

Enter design requirements:

Desired Closed Loop Gain:
Desired Min. Bandwidth:

Support | Ask An Expert

Need tech support for a product or design?
(Support FAQs)

Ask »

Follow Us Intersil Wins Outstanding Achievement in Web Development

Find pricing and availability for your part number. Order Parts, Eval Boards and Samples

Contact Sales »

myINTERSIL

Sign in to your account…
Search Orders    
Please Wait...

Toolbar

Simply Smarter